SA2200
SA2200
SA2200
SA2200
SA2200
SA2200
SA2200
SA2200
SA2200
SA2200

SA2200

SA2200 Portable Power Analyzer

Voltage Measuring Range
1~1,000 Vrms
Current Measuring Range
Max 6,000 A
Standard Compliance
Class A
Product Model
SA2200
Overview
Design Features
Specification
Accessory

SA2200 is a portable Class A power quality analyzer compliant with IEC 61000-4-30 Class A standard. It features high precision with basic voltage measurement accuracy of ±0.1%, supports tracking up to 100th harmonics, and has a 200kS/s sample rate for detailed waveform analysis. Equipped with a 32GB Micro SD card, GPS time synchronization, and multiple interfaces (USB Host, LAN, optional WIFI), it enables convenient data logging and analysis. With a 5.6' TFT LCD screen and 14 language options, it’s user-friendly for on-site troubleshooting of single or three-phase power systems.


Applications

  • Power Supply Maintenance

Diagnose voltage dips/swells and harmonics in grids to ensure stable power distribution.

  • Renewable Energy Systems

Monitor power quality of solar/wind installations, optimizing energy conversion efficiency.

  • Industrial Facilities:

Analyze factory power networks to prevent equipment damage from transients or unbalances.

  • Commercial Buildings

Track energy consumption and power factor to reduce waste in HVAC and lighting systems.

  • Electrical Engineering

Validate compliance with international standards during system design and commissioning.

  • Smart Grid Management:

Identify grid anomalies in real time, supporting efficient power network operation and maintenance.


Harmonics

Track harmonics up to 100th


Phase Diagram

Shows the relationship between voltage and current phases, helping to assess the balance of three-phase systems through visual representation.

Powerful logger function

Enables continuous recording of selected parameters over time, with sufficient storage capacity to meet common monitoring needs.

Data analyze in PC software

Allows for further processing and review of recorded data via computer software, supporting basic analysis and report generation.

Voltage/Current/FrequencyMeasurement RangeResolutionAccuracy
Vrms(AC+DC)1 ~ 120Vrms0.001Vrms±0.1% of nominal voltage
120Vrms~400Vrms0.01Vrms
400Vrms~1000Vrms0.1Vrms
Vpk1 ~ 1400Vpk0.01Vpk±0.5% of nominal voltage             
V(Crest Factor)1.0 ~ >2.80.01±5%
Arms(AC)       10mV/A0~150A0.01A±0.1%±0.1A
       1mV/A1~2000A0.01A±0.1%±0.1A
       65mV/1000A 10~6000A0.01A±0.1%±0.2A
A(Crest Factor)1 ~ 100.01±5%
Frequency42.5~57.5(50Hz nominal)0.01Hz±0.01Hz
51~69(60Hz nominal)0.01Hz±0.01Hz
320~480(400Hz nominal)0.01Hz±0.01Hz
Dips & Swells
Vrms1/20 ~ 200% of nominal voltage 0.01Vrms±0.2%
Arms1/2depends oncurrent clamps0.01A±1% 
Harmonic (IEC61000-4-7)
Harmonic Number

1 ~ 100(50/60Hz) (IEC61000-4-7) 

1~12(400Hz)

Harmonic Voltage %f0.0 ~ 100.0%0.01%±0.1%±nx0.1%
Harmonic Current %f0.0 ~ 100.0%0.01%±0.1%±nx0.1%
THD0.0 ~ 100.0%0.01%±2.5%
Phase-180° ~180°0.1°± nx0.1°
Power and Energy
P, S, Q1Max. 6000MW0.1kW±1%±10 digits
PF & cosФ0 ~ 10.01±0.01
kWh, kVAh, kvarhdepends on nominal voltage and current clamps±1%±10 digits
Flicker (IEC61000-4-15)
Pst(10min)/Plt (2 hrs)0.00 ~ 20.000.01±5%
Unbalance
Voltage0.0 ~ 20.0%0.10%±0.1%
Current0.0 ~ 20.0%0.10%±1%
Voltage Phase-360° ~ 0°0.1°±0.1°
Current Phase-360° ~ 0°0.1°±0.5°
Voltage Transient
Vpk±6000Vpk0.01V±15%
Vrms10 ~ 1000Vrms0.01V±2.5%
Min. Test Time5us
Inrush Current
Armsdepends on current clamps0.01A±1%±5digits
Inrush Duration1 ~ 32min selectable10ms±20ms
Mains Signaling
Signaling Frequency60-3000Hz0.1Hz
Relative V%0%-100%0.10%±0.4%
Absolute V3s (3s average)0.0-1000V0.1V±5% of Nominal voltage
Logger
Recordinguser-defined parameters for 4 phases at the same time
MemoryData stored in   Micro SD card, 32GB
Duration Time2 hrs to 1 year, depends on the recording items and time interval
Interval1s to 60 minutes
Monitor
Support EN50160 in default or user-defined standard


Channel(Voltage/Current)4/4
Voltage Range1-1000Vrms, 6000V transient voltage
Current Rangedepends on supplied current clamp
PC software analysisYes
Micro SD card(bulid-in)32GB
BatteryLithium ion, 5200mAh/>8h
Time SynchronizationGPS/Beidou(option)
interfaceUSB Host, LAN, WIFI
WIFI App●(option)
Screen5.6' TFT LCD with resolution640*480(SA2200)
Language

14-Chinese, English, French, German, Italian, Japanese, Korean, Polish,

Portuguese(Brazil/Portugal), Russian, Spanish(Latin/Spain), Turkish

Dimension/Weight          270*190*66mm/2.0kg
Wire Combinatios          

1Ø+NEUTRAL,1Ø SPLIT PHASE,1Ø IT NO NEUTRAL,

3Ø WYE, 3Ø DELTA, 3Ø IT, 3Ø HIGH LEG, 3Ø OPEN LEG, 

2-ELEMENT, 2 1/2-ELEMENT

Electrical SafetyIEC61010-1 ,Safety Degree: 600V CAT IV    1000V CAT III



SEE ALL
STANDARD ACCESSORIES
Voltage Test Leads

Voltage Test Leads

Aligator Clips

Aligator Clips

Power Cord

Power Cord

Power Adapter

Power Adapter

Soft Carry Bag

Soft Carry Bag

CD

CD

Sticker of Input Port

Sticker of Input Port

OPTIONAL ACCESSORY
Voltage Magnetic Probe

Voltage Magnetic Probe



Rated VoltageRated CurrentConnection SizeMetalColor
1000 V CAT Ⅲ, 600 V CAT Ⅳ1A4mmStainless SteelRed/Black



Hard Protection Case

Hard Protection Case

Dimension: 555×455×225 mm

C01-5A

C01-5A

Measurement Range0-5A
Output Voltage Ratio10mV/A
Accuracy0.2%
Frequency Characteristic45Hz~55Hz
Clamp Radius (mm)8
Dimension (mm)158×43×24
Cable Length (cm)200
Power


C02-100A

C02-100A

Measurement Range0-100A
Output Voltage Ratio10mV/A
Accuracy0.2%
Frequency Characteristic50Hz~400Hz
Clamp Radius (mm)8
Dimension (mm)171×46×27
Cable Length (cm)200
Power


C03-200A

C03-200A

Measurement Range1~200A
Output Voltage Ratio1mV/A
Accuracy0.2%
Frequency Characteristic50Hz~400Hz
Clamp Radius (mm)13
Dimension (mm)174×52×27
Cable Length (cm)200
Power


C04-1000A

C04-1000A

Measurement Range1~1000A
Output Voltage Ratio1mV/A
Accuracy1%
Frequency Characteristic40Hz~100kHz
Clamp Radius (mm)52
Dimension (mm)111×216×45
Cable Length (cm)200
Power


C05-1000AD

C05-1000AD

Measurement Range0.0~1000A (AC/DC)
Output Voltage Ratio1mV/A
Accuracy±3%
Frequency CharacteristicAC: 45Hz~400Hz
Clamp Radius (mm)30×35
Dimension (mm)122×70×33
Cable Length (cm)150
Power9V Dry cell 6LR61


C06-1500A

C06-1500A

Measurement Range10~1500A
Output Voltage Ratio@50Hz100mV/1000A
Accuracy±0.5%+Position Error
Maximum Allowable Input
100kA
Phase Error<±1°
Noise
<2mVrms (10Hz~10kHz)
Frequency Characteristic10Hz~10kHz (-3dB)
Weight
110g
Length
200cm
CT Perimeter
35cm
Measurement Position Error±1%


C07-3000A

C07-3000A

Measurement Range15~3000A
Output Voltage Ratio@50Hz65mV/1000A
Accuracy±1%+Position Error
Maximum Allowable Input100kA
Phase Error<±1°
Noise<2mVrms (10Hz~10kHz)
Frequency Characteristic10Hz~10kHz (-3dB)
Weight130g
Length200cm
CT Perimeter50cm
Measurement Position Error±2%


C08-6000A

C08-6000A

Measurement Range20~6000A
Output Voltage Ratio@50Hz65mV/1000A
Accuracy±1%+Position Error
Maximum Allowable Input100kA
Phase Error<±1°
Noise<2mVrms (10Hz~10kHz)
Frequency Characteristic10Hz~10kHz (-3dB)
Weight150g
Length200cm
CT Perimeter80cm
Measurement Position Error±2%


Beidou/GPS Receiver

Beidou/GPS Receiver

Model
GN200B
Satellite System
GPS/BDS
Voltage3.3 V~5 V
Starting SpeedCold starting 30 s, Hot starting 1 s
InterfacePS/S
Lead Length5 m
Working Temperature0 ℃ ~ 45 
Storage Temperature-40 ℃ ~ +85 


SA2200 Battery

SA2200 Battery